德國P+F開關(guān)量輸入安全柵一級代理商
德國P+F開關(guān)式安全柵產(chǎn)品種類
KCD2-SR-Ex1.LB
開關(guān)放大器
1路隔離柵,24 V直流電源(電源軌),干觸點(diǎn)或NAMUR輸入,可用作信號分配器(1個(gè)輸入和2個(gè)輸出),繼電器觸點(diǎn)輸出,故障繼電器觸點(diǎn)輸出,線路故障檢測(LFD),外殼寬度12.5 mm,zui高SIL 2 acc。符合IEC 61508,額定電壓:19 ... 30 V DC
KCD2-SR-練習(xí)2
開關(guān)放大器
2通道隔離柵,24 V DC電源(電源導(dǎo)軌),干觸點(diǎn)或NAMUR輸入,繼電器觸點(diǎn)輸出,線路故障檢測(LFD),外殼寬度12.5 mm,zui高SIL 2 acc。符合IEC 61508,額定電壓:19 ... 30 V DC
KFD2-SR2-Ex1.W
開關(guān)放大器
1通道隔離柵,24 V直流電源(電源導(dǎo)軌),干觸點(diǎn)或NAMUR輸入,繼電器觸點(diǎn)輸出,線路故障檢測(LFD),可逆運(yùn)行模式,高達(dá)SIL 2 acc。符合IEC 61508 / IEC 61511
KFD2-SR2-Ex1.W.LB
開關(guān)放大器
1路隔離柵,24 V直流電源(電源軌),干觸點(diǎn)或NAMUR輸入,可用作信號分離器(1個(gè)輸入和2個(gè)輸出),繼電器觸點(diǎn)輸出,故障繼電器觸點(diǎn)輸出,線路故障檢測(LFD),可逆操作模式,zui高SIL 2 acc。符合IEC 61508 / IEC 61511標(biāo)準(zhǔn),額定電壓:20 ... 30 V DC
KFD2-SR2-Ex2.W
開關(guān)放大器
2通道隔離柵,24 V直流電源(電源導(dǎo)軌),干觸點(diǎn)或NAMUR輸入,繼電器觸點(diǎn)輸出,線路故障檢測(LFD),可逆運(yùn)行模式,高達(dá)SIL 2 acc。符合IEC 61508
KFD2-SOT3-Ex1.LB
開關(guān)放大器
1路隔離柵,24 V直流電源(電源導(dǎo)軌),干觸點(diǎn)或NAMUR輸入,被動(dòng)晶體管輸出,非極化,被動(dòng)故障輸出,非極化,線路故障檢測(LFD),可逆運(yùn)行模式,符合SIL 2 acc。符合IEC 61508,額定電壓:19 ... 30 V DC
KFD2-SOT3,練習(xí)2
開關(guān)放大器
2通道隔離柵,24 V直流電源(電源軌),干觸點(diǎn)或NAMUR輸入,2個(gè)無源晶體管輸出,可逆工作模式,線路故障檢測(LFD),高達(dá)SIL 2 acc。符合IEC 61508,額定電壓:19 ... 30 V DC
KCD2-SON-EX1
開關(guān)放大器
1通道隔離柵,24 V直流電源(電源導(dǎo)軌),干觸點(diǎn)或NAMUR輸入,2個(gè)無源晶體管輸出(電阻符合EN 60947-5-6),線路故障透明度(LFT),外殼寬度12.5 mm,高達(dá)SIL 2 acc。符合IEC 61508
KCD2-SOT-Ex1.LB
開關(guān)放大器
1路隔離柵,24 V直流電源(電源軌),干觸點(diǎn)或NAMUR輸入,2個(gè)無源晶體管輸出,可用作信號分離器(1個(gè)輸入和2個(gè)輸出),可逆操作模式,線路故障檢測(LFD)房屋寬度12.5毫米,高達(dá)SIL 2 acc。符合IEC 61508,額定電壓:19 ... 30 V DC
KCD2-SOT-練習(xí)2
開關(guān)放大器
2通道隔離柵,24 V直流電源(電源導(dǎo)軌),干觸點(diǎn)或NAMUR輸入,2個(gè)無源晶體管輸出,可逆工作模式,線路故障檢測(LFD),外殼寬度12.5 mm,zui高SIL 2 acc。符合IEC 61508,額定電壓:19 ... 30 V DC
德國P+F開關(guān)量輸入安全柵一級代理商


1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Rated voltage: 20 ... 30 V DC

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC
 
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC
 
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC

德國P+F開關(guān)量輸入安全柵一級代理商


1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Rated voltage: 20 ... 30 V DC

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC
 
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
 
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC
 
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC
COPYRIGHT @ 2016 上海維特銳實(shí)業(yè)發(fā)展有限公司     網(wǎng)站地圖    滬ICP備13015955號-31   GoogleSitemap    關(guān)于我們 新聞中心 產(chǎn)品中心 聯(lián)系我們

電話:
021-32205893
手機(jī):
13795311448
傳真:
021-52500777
點(diǎn)擊這里給我發(fā)消息
 

化工儀器網(wǎng)

推薦收藏該企業(yè)網(wǎng)站
新宾| 万山特区| 梁河县| 搜索| 迭部县| 偃师市| 栾城县| 东兰县| 澄城县| 道真| 新龙县| 崇仁县| 湖州市| 临城县| 日土县| 吉水县| 喀喇| 濉溪县| 榆中县| 隆回县| 邮箱| 沂南县| 昌图县| 禄劝| 阿拉善盟| 盐亭县| 黔东| 侯马市| 宁陕县| 上思县| 永州市| 宝山区| 武乡县| 毕节市| 周宁县| 家居| 广安市| 临城县| 寻乌县| 镇平县| 拜城县|